Rexroth A2f A2fo A2FM A2fe Hydraulic Pump and Motor From China

Rexroth A2f A2fo A2FM A2fe Hydraulic Pump and Motor From China

CZPT CZPT Motor A2FE Collection

A2FE180 hydraulic motor new model manufactured in Germany
 
CZPT mounted motor A2FE28, A2FE32, A2FE45, A2FE56, A2FE63, A2FE80, A2FE90, A2FE107, A2FE125, A2FE160, A2FE180,
A2FE250, A2FE355

Description  

Open up and closed circuits
Collection sixty one and sixty
Pressure:
Dimension 28 to180 Nominal strain 5800 psi (four hundred bar)/ Peak stress 6500 psi (450 bar)
Measurement 250 to 355 Nominal pressure 5100 psi (350 bar)/ Peak stress 5800 psi (400 bar)
 
The A2FE fixed plug-in motor with axial tapered piston rotary team of bent-axis design and style, for hydrostatic drives in open up and shut circuits
-Considerably-achieving integration in mechanical gearbox thanks to recessed mounting flange positioned in the center of the situation (very area-conserving construction)
-The output velocity is dependent on the movement of the pump and the displacement of the motor.
-The output torque boosts with the strain differential between the substantial-force and the reduced-stress aspect.
-Small proportions.
-Higher overall performance.
-Full unit, completely ready-assembled and examined.
-Simple to set up, just plug into the mechanical gearbox.
-No configuration technical specs to be noticed when putting in.
 
Technological Data 
Table of values (theoretical values, without efficiency and tolerances values rounded)

CZPT A2FE motor A2FE28 A2FE32 A2FE45 A2FE56 A2FE63 A2FE80  
Displacement Vg cm3 28.one 32 45.six fifty six.1 sixty three eighty.4  
Pace maximum nnom rpm 6300 6300 5600 5000 5000 4500  
nmax2) rpm 6900 6900 6200 5500 5500 5000  
Input flow Vg qV L/min 177 202 255 281 315 362  
Torque at Vg and Dp = 350 bar T Nm 157 178 254 313 351  
Dp = four hundred bar T Nm 179 204 290 357 401  
Rotary stiffness c kNm/ rad two.ninety three three.12 4.18 5.94 six.twenty five 8.73  
Second of inertia JGR  kgm2 .0012 .0012 .0571 .0042 .0042 .0072  
Optimum angular a rad/s2 6500 6500 14600 7500 7500 6000  
Scenario volume V  L .2 .two .33 .forty five .forty five .55  
Mass (approx.) m kg ten.5 10.five 15 eighteen 19 23  
Dimension A2FE90 A2FE107 A2FE125 A2FE160 A2FE180 A2FE250 A2FE355
Displacement Vg cm3 ninety 106.7 one hundred twenty five a hundred and sixty.four one hundred eighty 250 355
Pace optimum nnom rpm 4500 4000 4000 3600 3600 2700 2240
nmax2) rpm 5000 4400 4400 4000 4000
Input circulation qV L/min 405 427 500 577 648 675 795
Torque at Vg Dp = 350 bar T 501 594 696 893 1003 1393 1978
Dp = 400 bar T 573 679 796 1571 1146
Rotary stiffness c kNm/rad nine.fourteen eleven.two eleven.9 seventeen.4 eighteen.2 seventy three.1 ninety six.1
Instant of inertia JGR kgm2 .0072 .0116 .0116 .571 .571 .061 .102
Highest angular a rad/s2 6000 4500 4500 3500 3500 ten thousand 8300
Case quantity V L .fifty five .eight .8 1.one one.1 2.five three.five
Mass (approx.) m kg 25 34 36 47 forty eight eighty two one hundred ten

CZPT fluid
Ahead of beginning venture plHangCZPT, please refer to our knowledge sheets RE 95710 (mineral oil), RE 95711 (environmentally appropriate hydraulic fluids) and RE 95712 (HFD hydraulic fluids) and RE 95713 (HFA, HFB, HFC hydraulic fluids) for comprehensive details relating to the decision of hydraulic fluid and software conditions. The plug-in motor A2FE is not appropriate for operation with HFA hydraulic fluid. If HFB, HFC or HFD or environmentally appropriate hydraulic fluids are used, the constraints regarding technological info or other seals should be observed.
Particulars regarding the selection of hydraulic fluid
The correct choice of hydraulic fluid needs understanding of the running temperature in relation to the ambient temperature: in a shut circuit, the circuit temperature, in an open circuit, the reservoir temperature. The hydraulic fluid ought to be chosen so that the operating viscosity in the working temperature variety is inside of the the best possible range (νopt), see shaded spot of the choice diagram. We recommended that the larger viscosity class be picked in every case. Instance: At an ambient temperature of X °C, an functioning temperature of 60 °C is established in the circuit. In the optimum functioning viscosity variety (νopt., shaded location) this corresponds to the viscosity courses VG 46 or VG 68 to be selected: VG 68.
Be aware: The situation drain temperature, which is impacted by pressure and speed, can be greater than the circuit temperature or reservoir temperature. At no stage of the ingredient may possibly the temperature be higher than 115 °C. The temperature distinction specified below is to be taken into account when deciding the viscosity in the bearing. If the over conditions cannot be preserved thanks to severe working parameters, we suggest the use of a flushing and increase force valve.
Shaft seal
Permissible stress loading the provider daily life of the shaft seal is affected by the pace of the axial piston device and the situation drain force (scenario pressure). The mean differential stress of two bar among the circumstance and the ambient force may not be enduringly exceeded at typical running temperature. For a higher differential force at decreased pace, see diagram. Momentary stress spikes (t < 0.1 s) of up to 10 bar are permitted. The service life of the shaft seal decreases with an increase in the frequency of pressure spikes.

 

Rexroth A2f A2fo A2FM A2fe Hydraulic Pump and Motor From China

TAGs: