Rexroth A2fe250 355 Hydraulic Axial Piston Motor for Excavator

Rexroth A2fe250  355 Hydraulic Axial Piston Motor for Excavator

CZPT A2fe250 /355 CZPT axial piston  Motor   for Excavator

Brueninghaus Hydromatik CZPT A2FE motor
 
CZPT fastened motor A2FE28, A2FE32, A2FE45, A2FE56, A2FE63, A2FE80, A2FE90, A2FE107, A2FE125, A2FE160, A2FE180,
A2FE250, A2FE355

Description  

Open up and closed circuits
Sequence 61 and sixty
Force:
Dimensions 28 to180 Nominal strain 5800 psi (four hundred bar)/ Peak force 6500 psi (450 bar)
Dimension 250 to 355 Nominal pressure 5100 psi (350 bar)/ Peak pressure 5800 psi (400 bar)
 
The A2FE fastened plug-in motor with axial tapered piston rotary team of bent-axis layout, for hydrostatic drives in open and shut circuits
-Significantly-achieving integration in mechanical gearbox because of to recessed mounting flange located in the centre of the scenario (incredibly space-preserving construction)
-The output velocity is dependent on the flow of the pump and the displacement of the motor.
-The output torque boosts with the stress differential among the large-force and the lower-stress aspect.
-Modest proportions.
-Substantial total performance.
-Complete unit, completely ready-assembled and tested.
-Simple to put in, merely plug into the mechanical gearbox.
-No configuration specifications to be noticed when putting in.
 
Technological Data 
Desk of values (theoretical values, without efficiency and tolerances values rounded)

CZPT A2FE motor A2FE28 A2FE32 A2FE45 A2FE56 A2FE63 A2FE80  
Displacement Vg cm3 28.1 32 forty five.6 56.one sixty three 80.4  
Velocity maximum nnom rpm 6300 6300 5600 5000 5000 4500  
nmax2) rpm 6900 6900 6200 5500 5500 5000  
Input flow Vg qV L/min 177 202 255 281 315 362  
Torque at Vg and Dp = 350 bar T Nm 157 178 254 313 351  
Dp = four hundred bar T Nm 179 204 290 357 401  
Rotary stiffness c kNm/ rad 2.93 3.twelve four.18 five.94 six.25 eight.seventy three  
Moment of inertia JGR  kgm2 .0012 .0012 .0571 .0042 .0042 .0072  
Optimum angular a rad/s2 6500 6500 14600 7500 7500 6000  
Scenario quantity V  L .two .two .33 .45 .forty five .fifty five  
Mass (approx.) m kg ten.five 10.5 15 18 19 23  
Measurement A2FE90 A2FE107 A2FE125 A2FE160 A2FE180 A2FE250 A2FE355
Displacement Vg cm3 90 106.seven 125 one hundred sixty.4 one hundred eighty 250 355
Speed greatest nnom rpm 4500 4000 4000 3600 3600 2700 2240
nmax2) rpm 5000 4400 4400 4000 4000
Enter stream qV L/min 405 427 five hundred 577 648 675 795
Torque at Vg Dp = 350 bar T 501 594 696 893 1003 1393 1978
Dp = four hundred bar T 573 679 796 1571 1146
Rotary stiffness c kNm/rad 9.14 11.2 eleven.9 17.4 18.two 73.one ninety six.1
Second of inertia JGR kgm2 .0072 .0116 .0116 .571 .571 .061 .102
Maximum angular a rad/s2 6000 4500 4500 3500 3500 10000 8300
Situation volume V L .fifty five .8 .eight one.1 one.1 two.5 3.five
Mass (approx.) m kg twenty five 34 36 forty seven forty eight eighty two a hundred and ten

CZPT fluid
Just before beginning task plHangCZPT, please refer to our knowledge sheets RE 95710 (mineral oil), RE 95711 (environmentally suitable hydraulic fluids) and RE 95712 (HFD hydraulic fluids) and RE 95713 (HFA, HFB, HFC hydraulic fluids) for detailed info concerning the option of hydraulic fluid and application conditions. The plug-in motor A2FE is not suited for procedure with HFA hydraulic fluid. If HFB, HFC or HFD or environmentally acceptable hydraulic fluids are utilized, the restrictions relating to complex info or other seals need to be noticed.
Information concerning the option of hydraulic fluid
The appropriate option of hydraulic fluid calls for information of the functioning temperature in relation to the ambient temperature: in a shut circuit, the circuit temperature, in an open up circuit, the reservoir temperature. The hydraulic fluid need to be chosen so that the working viscosity in the functioning temperature assortment is inside the ideal range (νopt), see shaded area of the selection diagram. We advised that the larger viscosity course be picked in each and every case. Illustration: At an ambient temperature of X °C, an functioning temperature of sixty °C is established in the circuit. In the optimum operating viscosity selection (νopt., shaded location) this corresponds to the viscosity courses VG 46 or VG 68 to be chosen: VG sixty eight.
Note: The situation drain temperature, which is impacted by strain and pace, can be higher than the circuit temperature or reservoir temperature. At no stage of the ingredient could the temperature be higher than a hundred and fifteen °C. The temperature big difference specified beneath is to be taken into account when figuring out the viscosity in the bearing. If the over circumstances are not able to be preserved because of to severe working parameters, we recommend the use of a flushing and increase strain valve.
Shaft seal
Permissible stress loading the services lifestyle of the shaft seal is affected by the pace of the axial piston unit and the circumstance drain force (scenario stress). The indicate differential pressure of two bar between the case and the ambient strain may possibly not be enduringly exceeded at regular functioning temperature. For a increased differential force at lowered velocity, see diagram. Momentary force spikes (t < 0.1 s) of up to 10 bar are permitted. The service life of the shaft seal decreases with an increase in the frequency of pressure spikes.

 

Rexroth A2fe250  355 Hydraulic Axial Piston Motor for Excavator

TAGs: